A three-belt package also allows you to have a clean, dry belt on hand when laundering your used belt.
To apply the belt, wrap around your waist above your exit site with the outer most flap above your exit site and secure contact closure. Open up both flaps and take transfer unit and place in elastic pouch. Next run the catheter tube across the contact closure flaps and secure by wrapping the flap around the tubing. Repeat for both contact closure flaps. To increase stabilization, one can apply the self-adhesive band that comes with the belt to the catheter tube. The belt SHOULD NEVER come in contact with the exit site. The exit site should be cleaned and maintained per your physician or nurse's instructions.
To clean the belt, we recommend hand washing the belts with a mild liquid detergent and cold water. Rinse thoroughly and air dry only. For extremely soiled belts, one can put a little hydrogen peroxide into the wash water, the peroxide will act as a natural bleaching agent. DO NOT put in a washing machine or dryer.
The PD-Belts come in 5 convenient sizes to accommodate a wide range of patients. For sizing measure around abdomen a few inches above the exit site: X-Small (16"-24"), Small (23"-36"), Medium (30"-44"), Large (36"-48"), X-Large (46"-58")
The proper location is found by creating a soft loop with the catheter as it exits the abdomen. Attach to belt with the Velcro tabs. Place the connector securely into the pocket. Re-adjust for maximum comfort and when you are satisfied, release the outer Velcro flap Tap "A" (the one farthest from the pocket), and glue the tacky back surface of the small piece of Velcro, included with these instructions, exactly where the tube intersects Tab "A." Make sure the tube is clean and dry for better adhesion. Each Velcro band should last more than a month even with showering daily, provided it has a chance to "cure" for several hours before getting wet again.
To perform your exchange, loosen your clothing, double check that your tube is secure at tab "A" by solidly pinching it (if you use the Velcro band around the catheter this is unnecessary), unfasten tab "C," then slide the connector out of pocket "D." You can now do the exchange as instructed. You will, of course, want to protect yourself by being very careful while you handle your bags on your I/V pole. Even the PD-BELT™ won't totally protect your exit site if you drop the full bag of fluid suddenly. Use both hands to hang your bags and let your PD-BELT™ hold your tube in position. When the exchange is done simply replace the connector in the belt pocket "D," re-secure the middle tab "C" over the tube, adjust the belt size if necessary, then refasten your clothing and resume your normal activities.
After you have showered with your wet belt on, dry off and fasten a fresh, dry belt approximately 1" above the one you are wearing. On the wet belt, unfasten tab "C," remove the connector from the pocket "D" and place it into the pocket "D" of the dry belt. Fasten tab "C." Now unfasten tab "A" on the wet belt and remove the catheter (with the self-adhesive Velcro band attached). Pinch the Velcro band around the catheter to confirm that the adhesive is holding. The catheter will now swing away from the wet belt. Unfasten the wet belt and carefully remove it by sliding it away from under the catheter loop. Fasten the catheter to the dry belt at tab "A", close tab "A" and adjust the belt to the proper height.
As you bloat or shrink during the day or night either from the dialysis process or from meals, just tighten or loosen your belt for maximum comfort. Small changes in girth will be accommodated by the give of the elastic. More expansive adjustments will require releasing the Velcro closure and repositioning to the proper size. You can medicate your exit site while wearing your PD-BELT™. Simply secure your tube to the belt as you normally would. Apply whichever ointment, cream or liquid your doctor have prescribed and place a folded 2" by 2" strip of gauze under the tube at the exit site for cushioning and another strip of gauze, the same size, over the top and securing it with paper tape. The paper tape will hold without curling if it is positioned vertically (up and down) and place under the PD-BELT™.
IMPORTANT: Try to wear the lowest cut underwear and loose clothing to prevent rubbing at the exit site.
If your local clinic or office does not currently carry or offer the PD-BELT™, download and print this flyer and take it in to encourage them to carry it.